Wuxi Golden Composites Co.,Ltd. Phenolic product system mainly include of Pultruded Phenolic Grating and Stairs, Molded Phenolic Grating and Stairs, and other Phenolic Product. which is optimal in conditions where fire resistance,low smoke and low toxic fumes are critical concerns.The phenolic product has widely used as petroleum platform、personnel walkways,catwalks, ladders, and Walkways or areas which may be used for escape, or access for firefighting, emergency operation or rescue.

The phenolic pultruded grating have passed U.S.Goast Guard Level 3 and Level 2 fire integrity test, and attained the USCG L2 Approval Certificate, and ABS Certificate and NK Certificate

The Properties of Phenolic Grating

Property Index Standard
Fire Retardant

Flame Spread index ≤10

ASTM-E84
Fire Resistance

After burn for one hour, its construction is still strong

ASTM E-119
Load

After burn for one hour, its load ≥94 lb/ft2, meet the requirement of USCG Structural fire integrity test Level 2

ASTM E-119
Fire Resistance

Burning Rate =0, Meet ASTM D-635

ASTM D-635
Corrosion Resistant

Corrosion Resistant

 
Use Temperature

Use temperature no more than 180℃

 

Specification Data

1.Pultruded Phenolic Grating

规格 高度(mm) 空隙率 工字钢数/英尺 中心距 (mm) 单重 (kg/m2)
PPI-15-60 38.1 60% 8 38.1 16.0
PPI-15-50 38.1 50% 10 30.5 19.0
PPI-15-40 38.1 40% 12 25.4 22.7

2.Molded Phenolic Grating

3.Other Phenolic Product

We also product other Phenolic product, For example, Phenolic Round Tube, Phenolic Square Tube, Phenolic I-bar,ect.

Application:

Our Phenolic Grating can be used in Lifeboat embarkation ortemporary safe refuge stations in open deck areas, Cargo Tank, Open deckor semi-enclose, ect. Such as the following:

◆ All Personnel walkways;

◆ Platform or access area;

◆ Platform or access area;

◆ v;

◆ Wave Zone Areas, Wind Walls;

◆ Walkway or exit for Pipe tunnel, Double bottom underground

 

 

 

 

 

 

 

 

 

 

Load Table for Phenolic Grating WPPI-1560

1、Test Result for Uniform Load

Load Deflection(mm)@Indicated Uniform Load(kg/SQ-METER) Load At
Span mm  244  367  489  734  1468  2446  4893 6.35MM Deflection 9.525MM Deflection
305 0.03 0.03 0.06 0.08 0.14 0.25 0.5  
457 0.06 0.08 0.14 0.2 0.39 0.64 1.29    
610 0.14 0.2 0.25 0.39 0.78 1.29 2.57    
762 0.28 0.42 0.56 0.84 1.65 2.77 5.53 5561  
914 0.59 0.89 1.17 1.76 3.52 5.87 11.73 2620 3932
1067 0.89 1.37 1.82 2.71 5.45 9.08   1695 2540
1219 1.59 2.4 3.21 4.81 9.61     960 1439
1371 2.49 3.72 4.95 7.43 14.86     620 929
1524 3.66 5.48 7.32 10.95       418 630
1676 5.87 8.8 11.73         264 391
1829 7.91 11.87           193 290

2、Test Result for Concentrated Load

Load Deflection(mm)@Indicated Concentrated Load(kg) Load At
Span mm  45  91  182  227  341  455  909 6.35MM Deflection 9.525MM Deflection
305 0.17 0.25 0.42 0.47 0.61 0.73 1.15    
457 0.22 0.39 0.61 0.75 1.01 1.23 2.21    
610 0.36 0.56 0.92 1.06 1.48 1.84 3.32    
762 0.36 0.73 1.45 1.79 2.65 3.49 6.73 857  
914 0.73 1.34 2.49 3.07 4.65 6.06 11.82 479 720
1067 0.78 1.65 3.38 4.19 6.23 8.47   340 517
1219 1.31 2.6 5.06 6.37 9.53 12.66   227 342
1371 1.79 3.58 7.07 8.69 12.99     164 252
1524 2.29 4.72 9.39 11.79       123 184
1676 3.55 6.87 13.36 16.62       86 128
1829 4.25 8.47 16.79 21.01       68 102

Note:Typical span 1200mm,the load is 2000kg/m2,the load deflection is ≤12mm。

 
 